Detail publikace
Differences in the accuracy of test methods in the field of testing aggregate and determination of their causes
UXA, R. VYMAZAL, T.
Originální název
Differences in the accuracy of test methods in the field of testing aggregate and determination of their causes
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
The article is based on the authors’ many years of experience in providing laboratory proficiency testing including organization of proficiency testing by interlaboratory comparison. In the introduction are compared the basic tests in the field of aggregates, based on their coefficient of variation. Another part details the influence of each testing stage (sampling, sample preparation and the test itself) on the accuracy of the test results and proposes possible measures to reduce their variance.
Klíčová slova
Testing, aggregate
Autoři
UXA, R.; VYMAZAL, T.
Vydáno
16. 7. 2018
Nakladatel
IOP Publishing
Místo
Bristol
ISSN
1757-8981
Periodikum
IOP Conference Series: Materials Science and Engineering
Ročník
385
Číslo
1
Stát
Spojené království Velké Británie a Severního Irska
Strany od
1
Strany do
8
Strany počet
8
URL
Plný text v Digitální knihovně
BibTex
@inproceedings{BUT149770,
author="René {Uxa} and Tomáš {Vymazal}",
title="Differences in the accuracy of test methods in the field of testing aggregate and determination of their causes",
booktitle="Construmat 2018",
year="2018",
journal="IOP Conference Series: Materials Science and Engineering",
volume="385",
number="1",
pages="1--8",
publisher="IOP Publishing",
address="Bristol",
doi="10.1088/1757-899X/385/1/012060",
issn="1757-8981",