The Effect of Tissue Physiological Variability on Transurethral Ultrasound Therapy of the Prostate

SUOMI, V. TREEBY, B. JAROŠ, J. SAUNAVAARA, J. KIVINIEMI, A. BLANCO, R.

Originální název

The Effect of Tissue Physiological Variability on Transurethral Ultrasound Therapy of the Prostate

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

Therapeutic ultrasound is an established modality which can be used for minimally invasive treatment of prostate cancer. Computational simulation models were used to study the effect of natural physiological variations in tissue parameters on the efficacy of therapeutic ultrasound treatment in the prostate. The simulations were conducted on a clinical ultrasound therapy system using patient computed tomography (CT) data. The values of attenuation, perfusion, specific heat capacity and thermal conductivity were changed within their biological ranges to determine their effect on peak temperature and thermal dose volume. Increased attenuation was found to have the biggest effect on peak temperature with a 6.9% rise. The smallest effect was seen with perfusion with 0.2% variation in peak temperature. Thermal dose was mostly affected by specific heat capacity which showed a 20.7% increase in volume with reduced heat capacity. Thermal conductivity had the smallest effect on thermal dose with up to 2.1% increase in the volume with reduced thermal conductivity. These results can be used to estimate the expected interpatient variation during the therapeutic ultrasound treatment of the prostate.

Klíčová slova

Ultrasonic imaging, Thermal conductivity, Heating systems, Conductivity, Computational modeling, Attenuation, Probes

Autoři

SUOMI, V.; TREEBY, B.; JAROŠ, J.; SAUNAVAARA, J.; KIVINIEMI, A.; BLANCO, R.

Vydáno

1. 7. 2018

Nakladatel

Institute of Electrical and Electronics Engineers

Místo

Honolulu, HI

ISBN

978-1-5386-3646-6

Kniha

40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)

Strany od

5701

Strany do

5704

Strany počet

4

URL

BibTex

@inproceedings{BUT155005,
  author="SUOMI, V. and TREEBY, B. and JAROŠ, J. and SAUNAVAARA, J. and KIVINIEMI, A. and BLANCO, R.",
  title="The Effect of Tissue Physiological Variability on Transurethral Ultrasound Therapy of the Prostate",
  booktitle="40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)",
  year="2018",
  pages="5701--5704",
  publisher="Institute of Electrical and Electronics Engineers",
  address="Honolulu, HI",
  doi="10.1109/EMBC.2018.8513548",
  isbn="978-1-5386-3646-6",
  url="https://ieeexplore.ieee.org/document/8513548"
}