High sensitivity deep-UV LED-based z-cell photometric detector for capillary liquid chromatography

LI, Y. NESTERENKO, P. STANLEY, R. PAULL, B. MACKA, M.

Originální název

High sensitivity deep-UV LED-based z-cell photometric detector for capillary liquid chromatography

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

A new high sensitivity deep-UV LED photometric detector with a z-type flow cell (45 nL or 180 nL) for miniaturised and portable capillary liquid chromatography (LC) was designed and fabricated to overcome sensitivity limitations due to short pathlength in on-capillary detectors. The new detector has a 10 mm geometric pathlength and uses high intensity light-emitting diodes (LED) as light sources in the deep-UV range (254 nm and 280 nm). No optical reference was necessary due to the low drift in the signal. Stray light was minimized by the use of an adjustable slit with a 0.5mm pinhole. The direct relationship between absorbance and concentration was obtained using dichromate to evaluate the sensitivity and the linearity range of the detector. Performance of the miniaturised version was compared with that obtained from a commercial benchtop detector for capillary LC under the same conditions using the same optical z-cell. The miniaturised version exhibited a superior performance across all parameters, including 3 times higher effective pathlength, 4 times higher upper limit of detector linearity, and 2-5 times lower stray light levels. An application of the new detector was shown with the detection of L-dopa, L-tyrosine, norfenefrine, phenylephrine and tyramine, separated using capillary LC. The baseline noise level recorded was as low as 3.9 mu AU. Further, the detector was applied in a miniaturised capillary LC for the indirect detection of common inorganic anions. In comparison to an on-capillary LED detector applied under similar chromatographic conditions, there was a 50 times higher signal to noise (S/N) ratio.

Klíčová slova

Deep UV LED; High-sensitivity z-cell; Absorbance detector; Capillary liquid chromatography; Portable liquid chromatography

Autoři

LI, Y.; NESTERENKO, P.; STANLEY, R.; PAULL, B.; MACKA, M.

Vydáno

22. 11. 2018

ISSN

0003-2670

Periodikum

ANALYTICA CHIMICA ACTA

Ročník

1032

Číslo

1

Stát

Nizozemsko

Strany od

197

Strany do

202

Strany počet

6

BibTex

@article{BUT156130,
  author="Yan {Li} and Pavel {Nesterenko} and Roger {Stanley} and Brett {Paull} and Miroslav {Macka}",
  title="High sensitivity deep-UV LED-based z-cell photometric detector for capillary liquid chromatography",
  journal="ANALYTICA CHIMICA ACTA",
  year="2018",
  volume="1032",
  number="1",
  pages="197--202",
  doi="10.1016/j.aca.2018.06.005",
  issn="0003-2670"
}