Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
MALÝ, M. SAPÍK, M. CEJPEK, O. WIGLEY, G. KATOLICKÝ, J. JEDELSKÝ, J.
Originální název
Effect of spill orifice geometry on spray and control characteristics of spill-return pressure-swirl atomizers
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Many spray process technologies require variable liquid flow rates or droplet sizes. Frequently used Simplex atomizers, favoured for their simple construction, reliability and fine spray, have a limited regulation range due to their flow rate dependency on the square root of the inlet overpressure, pl. To overcome this drawback, spill-return versions of the atomizer were developed in the past but so far rarely investigated in depth. In this paper, small spill-return atomizers (SRAs) were designed and investigated experimentally using Phase Doppler Anemometry (PDA) and high-speed imaging with the aim to determine the effect of the spill orifice design, e.g. the positioning of the axial and off-axis spill orifices, their number and inclination on the control characteristics, nozzle efficiency and spray characteristics. Such detailed data were not to be found in the open literature. The off-axial spill orifice version produced a stable spray under all flow regimes investigated while the axially positioned spill orifice provided an unstable spray for low spill-to-feed ratios (SFR). However, the axially placed spill orifice was found to be more energy efficient as it required a lower spill flow rate to achieve the same injection flow rate. The radial position of the spill orifices affected the turndown ratio and liquid breakup nature. The atomizers with spill orifices placed close to the swirl chamber centreline generated a liquid sheet which disintegrated in short-wave breakup mode while the other atomizers demonstrated a long-wave breakup mode. This mode produced longer liquid breakup length and formed droplets with smaller Sauter mean diameters. Atomization efficiency was found to decrease linearly with SFR and almost inversely proportional to pl. These findings have produced practical guidelines and recommendations for atomizer designs to suit specific goals and are addressed to both atomizer designers and application engineers. The experimental data form a significant base to validate advanced numerical simulations of the SRA sprays.
Klíčová slova
Spill-return atomizer Spray cone angle PDA Sauter mean diameter Spill orifice Break up
Autoři
MALÝ, M.; SAPÍK, M.; CEJPEK, O.; WIGLEY, G.; KATOLICKÝ, J.; JEDELSKÝ, J.
Vydáno
1. 9. 2019
Nakladatel
Elsevier
ISSN
0894-1777
Periodikum
EXPERIMENTAL THERMAL AND FLUID SCIENCE
Ročník
106
Číslo
1
Stát
Spojené státy americké
Strany od
159
Strany do
170
Strany počet
12
URL
https://www.sciencedirect.com/science/article/pii/S0894177718319964?dgcid=author
BibTex
@article{BUT156813, author="Milan {Malý} and Marcel {Sapík} and Ondřej {Cejpek} and Graham {Wigley} and Jaroslav {Katolický} and Jan {Jedelský}", title="Effect of spill orifice geometry on spray and control characteristics of spill-return pressure-swirl atomizers", journal="EXPERIMENTAL THERMAL AND FLUID SCIENCE", year="2019", volume="106", number="1", pages="159--170", doi="10.1016/j.expthermflusci.2019.04.014", issn="0894-1777", url="https://www.sciencedirect.com/science/article/pii/S0894177718319964?dgcid=author" }