Originální abstrakt
The main goal of this study was to make a comparison of aortic flow timing obtained by PW Doppler in four aortic sections with timing of − dZ/dt max obtained by bioimpedance measurement in nine locations on the thorax and neck. This knowledge is essential for determination of which bioimpedance channel could be used as a proximal for evaluation of pulse wave velocity (PWV) from the beginning of the ascending aorta or another aortic section. Time intervals between the Doppler flow and bioimpedance information (− dZ/dt max) were compared. It was found that the channel located on the left part of the neck is the most suitable as a proximal bioimpedance channel which corresponds to the aortic arch. This match is obtained with regard to the value of the time difference as well as inter-subject stability. This channel can be used as a proximal for evaluation of pulse wave velocity from the aortic arch to the desired distal target place in the body when distance between measured parts is known. The data from 35 volunteers with adequate signal quality were analyzed.
Klíčová slova
Bioimpedance, Doppler ultrasound, Pulse wave velocity (PWV), Pulse transit time (PTT)
Autoři
SOUKUP, L.; HRUŠKOVÁ, J.; JURÁK, P.; HALÁMEK, J.; ZÁVODNÁ, E.; VIŠČOR, I.; MATEJKOVÁ, M.; VONDRA, V.
Vydáno
19. 5. 2019
Nakladatel
SPRINGER HEIDELBERG
Místo
TIERGARTENSTRASSE 17, D-69121 HEIDELBERG, GERMANY
ISSN
1741-0444
Periodikum
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
Ročník
57
Číslo
5
Stát
Spolková republika Německo
Strany od
1151
Strany do
1158
Strany počet
8
URL
https://link.springer.com/article/10.1007%2Fs11517-018-01948-x
BibTex
@article{BUT158724, author="Ladislav {Soukup} and Jana {Hrušková} and Pavel {Jurák} and Josef {Halámek} and Eva {Závodná} and Ivo {Viščor} and Magdaléna {Bačo Matejková} and Vlastimil {Vondra}", title="Comparison of noninvasive pulse transit time determined from Doppler aortic flow and multichannel bioimpedance plethysmography", journal="MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING", year="2019", volume="57", number="5", pages="1151--1158", doi="10.1007/s11517-018-01948-x", issn="1741-0444", url="https://link.springer.com/article/10.1007%2Fs11517-018-01948-x" }