Detail publikace

Using a thermal manikin to determine evaporative resistance and thermal insulation – A comparison of methods

TOMA, R. KUKLANE, K. FOJTLÍN, M. FIŠER, J. JÍCHA, M.

Originální název

Using a thermal manikin to determine evaporative resistance and thermal insulation – A comparison of methods

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

Heat transfer from the human body, especially through the evaporation of sweat from the skin, is often restricted when protective clothing is used, which may result in overheating. For this reason, it is important to consider the parameters of protective clothing as input data in physiological models, such as predicted heat strain. The two most important parameters are thermal insulation and evaporative resistance with clothing area factor strongly influencing both. These parameters were determined for two clothing ensembles using a (dry) non-sweating thermal manikin. First, the clothing area factor was determined using the photographic method. Second, thermal insulation was measured in both static and dynamic conditions, and multiple equations for predicting dynamic thermal insulation from static ones were evaluated. Third, methodology for measuring evaporative resistance based on pre-wetted skin was adopted and multiple corrections were assessed. Finally, sensitivity analyses were completed using PHS to determine the impact of different equations on the duration limited exposure. For the thermal insulation measurements, we found that predictive equation (32) from ISO 9920 was the most accurate, but choosing the correct equation for protective clothing proved challenging. Although a manikin’s surface temperature is widely used for calculating evaporative resistance, the skin temperature should be used instead, since it is correct from a physical point of view and there is a difference of up to 15% in the results. Because these measures are used in thermal risk analyses conditions, a high degree of accuracy and a knowledge of the inputs must be guaranteed.

Klíčová slova

Evaporative resistance, thermal manikin, resultant thermal insulation, protective clothing

Autoři

TOMA, R.; KUKLANE, K.; FOJTLÍN, M.; FIŠER, J.; JÍCHA, M.

Vydáno

14. 1. 2020

Nakladatel

SAGE Publications Ltd

Místo

USA

ISSN

1530-8057

Periodikum

Journal of Industrial Textiles

Ročník

2020

Číslo

1

Stát

Spojené státy americké

Strany od

1

Strany do

23

Strany počet

23

URL

BibTex

@article{BUT161349,
  author="Róbert {Toma} and Kalev {Kuklane} and Miloš {Fojtlín} and Jan {Fišer} and Miroslav {Jícha}",
  title="Using a thermal manikin to determine evaporative resistance and thermal insulation – A comparison of methods",
  journal="Journal of Industrial Textiles",
  year="2020",
  volume="2020",
  number="1",
  pages="1--23",
  doi="10.1177/1528083719900672",
  issn="1530-8057",
  url="https://journals.sagepub.com/doi/10.1177/1528083719900672"
}