Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
SEDLÁK, P. KUBERSKÝ, P.
Originální název
The Effect of the Orientation Towards Analyte Flow on Electrochemical Sensor Performance and Current Fluctuations
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Analyte flow influences the performance of every gas sensor; thus, most of these sensors usually contain a diffusion barrier (layer, cover, inlet) that can prevent the negative impact of a sudden change of direction and/or the rate of analyte flow, as well as various unwanted impacts from the surrounding environment. However, several measurement techniques use the modulation of the flow rate to enhance sensor properties or to extract more information about the chemical processes that occur on a sensitive layer or a working electrode. The paper deals with the experimental study on how the analyte flow rate and the orientation of the electrochemical sensor towards the analyte flow direction influence sensor performance and current fluctuations. Experiments were carried out on a semi-planar, three-electrode topology that enabled a direct exposure of the working (sensing) electrode to the analyte without any artificial diffusion barrier. The sensor was tested within the flow rate range of 0.1–1 L/min and the orientation of the sensor towards the analyte flow direction was gradually set to the four angles 0°, 45°, 90° and 270° in the middle of the test chamber, while the sensor was also investigated in the standard position at the bottom of the chamber.
Klíčová slova
analyte flow; current fluctuations; amperometric sensor; signal-to-noise ratio
Autoři
SEDLÁK, P.; KUBERSKÝ, P.
Vydáno
14. 2. 2020
Nakladatel
MDPI
Místo
ST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND
ISSN
1424-8220
Periodikum
SENSORS
Ročník
20
Číslo
4
Stát
Švýcarská konfederace
Strany od
1
Strany do
17
Strany počet
URL
https://www.mdpi.com/1424-8220/20/4/1038
Plný text v Digitální knihovně
http://hdl.handle.net/11012/184645
BibTex
@article{BUT162256, author="Petr {Sedlák} and Petr {Kuberský}", title="The Effect of the Orientation Towards Analyte Flow on Electrochemical Sensor Performance and Current Fluctuations", journal="SENSORS", year="2020", volume="20", number="4", pages="1--17", doi="10.3390/s20041038", issn="1424-8220", url="https://www.mdpi.com/1424-8220/20/4/1038" }