Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
MIKOVÁ, B. DVOŘÁK, M. RYŠAVÁ, L. KUBÁŇ, P.
Originální název
Hollow fiber liquid-phase microextraction at-line coupled to capillary electrophoresis for direct analysis of human body fluids
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
A simple and cheap all-in-one concept for at-line coupling of hollow fiber liquid-phase microextraction (HF-LPME) to commercial capillary electrophoresis (CE) is demonstrated, which enables direct analysis of complex samples. A disposable microextraction device compatible with injection systems of Agilent CE instruments is proposed that consists of a short segment of a porous HF attached to a tapered polypropylene holder. The holder maintains constant position of the HF in a CE vial during extraction and simultaneously it guides the injection end of a separation capillary into the HF lumen for automated CE injection and analysis. In a typical analytical procedure, the HF is impregnated with a water-immiscible solvent, its lumen is filled with 5 μL of an aqueous acceptor solution and the microextraction device is placed in a 2-mL glass CE vial containing 550 μL of a donor solution. The vial is agitated at 750 rpm for 10 min and the resulting acceptor solution is injected directly from the HF lumen into the commercial CE. No additional manual handling is required except for the transfer of the CE vial to the CE autosampler. Multiple complex samples can be simultaneously pretreated in a multiple-well plate format, thus significantly reducing total analysis time. Suitability of the analytical method is demonstrated by the direct determination of model basic drugs (nortriptyline, haloperidol, loperamide, and papaverine) in physiological solutions, urine and dried blood spot (DBS) samples. Repeatability of the method is better than 12.8%, extraction recoveries range between 34% and 76% and enrichment factors are 37 to 84. The method is linear in a range of two orders of magnitude (r2 ≥ 0.9977) with limits of detection 0.7 – 1.55 μg/L. The method has a high potential for the direct analysis of DBS samples since DBS elution and HF-LPME are performed simultaneously during the 10 min agitation. The manual DBS handling is thus reduced to inserting the DBS punch into the CE vial only. Moreover, the universal character of the HF-LPME might extend the applicability of the method to a wide range of analytes/matrices, and combination with other commercial detectors might improve selectivity/sensitivity of the CE analysis.
Klíčová slova
Basic drugs; Capillary electrophoresis; Dried blood spots; Hollow fiber liquid-phase microextraction; Supported liquid membrane; Urine
Autoři
MIKOVÁ, B.; DVOŘÁK, M.; RYŠAVÁ, L.; KUBÁŇ, P.
Vydáno
14. 4. 2020
ISSN
1520-6882
Periodikum
Analytical Chemistry
Ročník
92
Číslo
10
Stát
Spojené státy americké
Strany od
7171
Strany do
7178
Strany počet
8
URL
https://pubs.acs.org/doi/10.1021/acs.analchem.0c00697
BibTex
@article{BUT163502, author="Miková {Blanka} and Miloš {Dvořák} and Lenka {Ryšavá} and Pavel {Kubáň}", title="Hollow fiber liquid-phase microextraction at-line coupled to capillary electrophoresis for direct analysis of human body fluids", journal="Analytical Chemistry", year="2020", volume="92", number="10", pages="7171--7178", doi="10.1021/acs.analchem.0c00697", issn="1520-6882", url="https://pubs.acs.org/doi/10.1021/acs.analchem.0c00697" }