Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
VAŇOVÁ, V. SEDLÁČKOVÁ, E. HYNEK, D. RICHTERA, L. BYTEŠNÍKOVÁ, Z. ADAM, V.
Originální název
Highly selective and sensitive electrochemical biosensor based on electrochemically reduced graphene oxide for detection of miRNA as a cancer biomarker
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
Nowadays, cancer is one of the most outrageous diseases affecting millions of people throughout the world. In this study, the sensitive biosensor for miRNA-21 detection was developed. Through a facile sulfonamide coupling reaction a miRNA-21 specific DNA hybridization probe was immobilized onto a glassy carbon electrode (GCE) modified with electrochemical reduced graphene oxide (erGO). miRNA is a small non-coding RNA molecule which plays an important role in gene expression. The level of miRNA in extracellular fluids varying in the presence of cancer and it can serve as potential biomarker for early detection of cancer. An elevated level of miRNA-21 represents a common feature of pathological cell growth or cell stress and is connected with almost all types of cancer and with cardiovascular diseases, as well. The aim of this study was improve the electrochemical properties by using erGO as a modification for better sensitivity of the developed biosensor. After the modification with erGO, 1-amino-2-naphthol-4-sulfonic acid (AN-SO3-) was electrodeposited on the GCE surface. --Finally, the amino terminated capture probe was immobilized on the GCE via the sulfonamide coupling reaction. The developed biosensor for the detection of specific miRNA sequence was optimized and modified for using in further experiments.
Klíčová slova
Reduced graphene oxide; miRNA; biosensor; electrochemical detection
Autoři
VAŇOVÁ, V.; SEDLÁČKOVÁ, E.; HYNEK, D.; RICHTERA, L.; BYTEŠNÍKOVÁ, Z.; ADAM, V.
Vydáno
10. 6. 2020
Nakladatel
Tanger
ISBN
978-80-87294-95-6
Kniha
NANOCON 2019 CONFERENCE PROCEEDINGS
Edice
1.
Strany od
385
Strany do
390
Strany počet
6
URL
https://doi.org/10.37904/nanocon.2019.8615
Plný text v Digitální knihovně
http://hdl.handle.net/11012/196676
BibTex
@inproceedings{BUT164271, author="Veronika {Vaňová} and Eliška {Dostálová} and David {Hynek} and Lukáš {Richtera} and Zuzana {Bytešníková} and Vojtěch {Adam}", title="Highly selective and sensitive electrochemical biosensor based on electrochemically reduced graphene oxide for detection of miRNA as a cancer biomarker", booktitle="NANOCON 2019 CONFERENCE PROCEEDINGS", year="2020", series="1.", pages="385--390", publisher="Tanger", doi="10.37904/nanocon.2019.8615", isbn="978-80-87294-95-6", url="https://doi.org/10.37904/nanocon.2019.8615" }