Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
KŘIVÍK, P. BAČA, P. KAZELLE, J.
Originální název
Effect of ageing on the impedance of the lead-acid battery
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
The paper deals with the influence of ageing on the cell impedance parameters during discharging and charging of the lead acid cell. Z-modulus and phase angle of lead acid cell were measured for frequencies from 2570 Hz to 0.351 Hz. The results are based on the electrochemical impedance spectroscopy data. Impedance measurements during discharging and charging were performed on a new cell and on an aged cell before and after 100% DOD (depth of discharge) cycling. Accelerated ageing was performed by repeated deep discharge to 0.0 V. The results of impedance measurements on a lead-acid battery cell show that cell ageing associated with degradation mechanisms has a significant effect on impedance parameters. Measurement of the Z-modulus and the phase angle can be an indicator of degradation processes in the cell during ageing.
Klíčová slova
lead-acid batteries, impedance, SoC
Autoři
KŘIVÍK, P.; BAČA, P.; KAZELLE, J.
Vydáno
23. 2. 2021
Nakladatel
VUT v Brně
Místo
Brno
ISSN
2352-152X
Periodikum
Journal of Energy Storage
Ročník
36
Číslo
1
Stát
Nizozemsko
Strany od
Strany do
9
Strany počet
URL
https://www.sciencedirect.com/science/article/pii/S2352152X18304079
BibTex
@article{BUT169754, author="Petr {Křivík} and Petr {Bača} and Jiří {Kazelle}", title="Effect of ageing on the impedance of the lead-acid battery", journal="Journal of Energy Storage", year="2021", volume="36", number="1", pages="1--9", doi="10.1016/j.est.2021.102382", issn="2352-152X", url="https://www.sciencedirect.com/science/article/pii/S2352152X18304079" }