Detail publikace

Comparison of two different approaches for Spatial Resolution determination for X-ray Computed Tomography with helical scanning trajectory

LÁZŇOVSKÝ, J. BŘÍNEK, A. ŠALPLACHTA, J. ZIKMUND, T. PATAKOVA, Z. KAISER, J.

Originální název

Comparison of two different approaches for Spatial Resolution determination for X-ray Computed Tomography with helical scanning trajectory

Typ

článek ve sborníku mimo WoS a Scopus

Jazyk

angličtina

Originální abstrakt

The spatial resolution is still one of the essential parameters quantified in X-ray micro Computed Tomography for industrial applications. There is a number of approaches, how can be the spatial resolution determined. Our paper presents two of them: evaluation of the ruby sphere according to the ASTM E1695–95 guideline and bar pattern recognition included in the nanoQRM phantom. The main aim of this paper is to point out the aspects of the spatial resolution determination according to the selected approaches and to compare the possible differences in the resulting spatial resolution. Both approaches were tested on a helical scanning trajectory utilizing one custom–made phantom consisting of a ruby sphere and commercial nanoQRM within a single scan. Such a unique phantom allows for accurate comparison due to the ability to determine spatial resolution using both methods within a single scan. In general, both approaches determined the spatial resolution on the same value. The final difference is given by the discrete approach provided by nanoQRM.

Klíčová slova

X-ray computed tomography; Spatial resolution; Helical CT; Helical trajectory; nanoQRM; Modulation transfer function; microCT

Autoři

LÁZŇOVSKÝ, J.; BŘÍNEK, A.; ŠALPLACHTA, J.; ZIKMUND, T.; PATAKOVA, Z.; KAISER, J.

Vydáno

8. 2. 2022

Nakladatel

NDT.net

Místo

Wels, Austria

ISSN

1435-4934

Periodikum

The e-Journal of Nondestructive Testing

Stát

Spolková republika Německo

Strany od

1

Strany do

6

Strany počet

6

URL

BibTex

@inproceedings{BUT177511,
  author="Jakub {Lázňovský} and Adam {Břínek} and Jakub {Šalplachta} and Tomáš {Zikmund} and Zuzana {Patakova} and Jozef {Kaiser}",
  title="Comparison of two different approaches for Spatial Resolution determination for X-ray Computed Tomography with helical scanning trajectory",
  booktitle="11th Conference on Industrial Computed Tomography (iCT) 2022, 8-11 Feb, Wels, Austria",
  year="2022",
  journal="The e-Journal of Nondestructive Testing",
  pages="1--6",
  publisher="NDT.net",
  address="Wels, Austria",
  issn="1435-4934",
  url="https://www.ndt.net/article/ctc2022/papers/ICT2022_paper_id251.pdf"
}