Detail publikace

Decline in the Ultrasonic Pulse Velocity in Ceramic Tiles Depending on the Adhesive

KOCÁB, D. TOPOLÁŘ, L. ALEXA, M. LISZTWAN, D. ČANĚK, M.

Originální název

Decline in the Ultrasonic Pulse Velocity in Ceramic Tiles Depending on the Adhesive

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

The paper describes an experiment aimed at verifying the influence of the size of large-format tile segments and, primarily, the influence of various adhesives on the quality and behaviour of the tiles. Large-format tiles were attached in various ways to pre-prepared concrete panels with a thickness of 150 mm and surface dimensions of 2 m x 3 m. The adhesives used were varied as well as the size to which the large-format elements were cut. The quality of the tiling material was monitored non-destructively by running an ultrasonic pulse velocity test. It was found that while the size of the segments cut from the large-format tiles did not affect the ultrasonic pulse velocity, the adhesive used did.

Klíčová slova

Ceramic tile; large-format tile; adhesive; ultrasonic pulse velocity; non-destructive testing

Autoři

KOCÁB, D.; TOPOLÁŘ, L.; ALEXA, M.; LISZTWAN, D.; ČANĚK, M.

Vydáno

18. 8. 2023

Nakladatel

AIP Conference Proceedings

Místo

College Park, Maryland

ISBN

978-0-7354-4514-7

Kniha

Special Concrete and Composites 2021

ISSN

0094-243X

Periodikum

AIP conference proceedings

Ročník

2780

Číslo

2023

Stát

Spojené státy americké

Strany od

020011-1

Strany do

020011-5

Strany počet

5