Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
GRYSZEL, M. JAKEŠOVÁ, M. VU, X. INGEBRANDT, S. GLOWACKI, E.
Originální název
Elevating Platinum to Volumetric Capacitance: High Surface Area Electrodes through Reactive Pt Sputtering
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Platinum is the most widespread electrode material used for implantable biomedical and neuroelectronic devices, motivating exploring ways to improve its performance and understand its fundamental properties. Using reactive magnetron sputtering, PtOx is prepared, which upon partial reduction yields a porous thin-film form of platinum with favorable properties, notably record-low impedance values outcompeting other reports for platinum-based electrodes. It is established that its high electrochemical capacitance scales with thickness, in the way of volumetric capacitor materials like IrOx and poly(3,4-ethylenedioxythiophene), PEDOT. Unlike these two well-known analogs, however, it is found that PtOx capacitance is not caused by reversible pseudofaradaic reactions but rather due to high surface area. In contrast to IrOx, PtOx is not a reversible valence-change oxide, but rather a porous form of platinum. The findings show that this oxygen-containing form of Pt can place Pt electrodes on a level competitive with IrOx and PEDOT. Due to its relatively low cost and ease of preparation, PtOx can be a good choice for microfabricated bioelectronic devices. Platinum is used in many medical implants, but lags behind next-generation electrode materials in performance. How sputtered platinum oxide is a microfabricatable thin film material that provides bioelectronics electrodes with volumetric capacitance and low impedance that tweaks platinum to compete at the level of conducting polymers and IrOx is shown. image
Klíčová slova
bioelectronics; biomedical microdevices; electrochemistry; platinum; reactive sputtering
Autoři
GRYSZEL, M.; JAKEŠOVÁ, M.; VU, X.; INGEBRANDT, S.; GLOWACKI, E.
Vydáno
17. 5. 2024
Nakladatel
WILEY
Místo
HOBOKEN
ISSN
2192-2640
Periodikum
Advanced Healthcare Materials
Ročník
13
Číslo
5
Stát
Spojené království Velké Británie a Severního Irska
Strany počet
7
URL
https://onlinelibrary.wiley.com/doi/10.1002/adhm.202302400
Plný text v Digitální knihovně
http://hdl.handle.net/11012/249528
BibTex
@article{BUT188751, author="Maciej {Gryszel} and Marie {Jakešová} and Xuan Thang {Vu} and Sven {Ingebrandt} and Eric Daniel {Glowacki}", title="Elevating Platinum to Volumetric Capacitance: High Surface Area Electrodes through Reactive Pt Sputtering", journal="Advanced Healthcare Materials", year="2024", volume="13", number="5", pages="7", doi="10.1002/adhm.202302400", issn="2192-2640", url="https://onlinelibrary.wiley.com/doi/10.1002/adhm.202302400" }