Originální abstrakt
Thermal treatment of sludge represents a renewable energy source, which is presently widely investigated. However, thermal utilization of sludge requires some pre-treatment. The sludge has to be preheated and de-watered before combustion. The preheating has a significant effect on flocculation and consequently de-watering efficiency. In this work, we used a helical heat exchanger for the sludge preheating. Process water was used as the hot stream. Correlations necessary for design calculation of the helical heat exchanger were adopted from literature, in spite of some slight differences in the heat exchanger geometry. In order to validate and tune the design correlations, CFD simulations of the heat exchanger have been performed. Commercial code FLUENT 6.3 was used for all computations.
Klíčová slova
CFD, Helix heat exchanger, Sludge, Waste to energy
Autoři
PISKOVSKÝ, M.; HÁJEK, J.; KILKOVSKÝ, B.; ELSAESSER, T.; STEHLÍK, P.
Rok RIV
2007
Vydáno
18. 4. 2007
Místo
Chambery, FR
Strany od
471
Strany do
482
Strany počet
11
BibTex
@inproceedings{BUT22449, author="Martin {Piskovský} and Jiří {Hájek} and Bohuslav {Kilkovský} and Thomas {Elsässer} and Petr {Stehlík}", title="ANALYSIS OF HELICAL HEAT EXCHANGER WATER - SLUDGE BY CFD", booktitle="Proceedings of Heat-SET 2007", year="2007", series="Volume 1", pages="471--482", address="Chambery, FR" }