Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
VÍTEK, M. KOZUMPLÍK, J.
Originální název
DETECTION OF QRS BOUNDARIES AND T WAVE END IN MULTILEAD ECG SIGNALS
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
In this paper, we propose a robust multilead electrocardiogram (ECG) detection system based on a continuous wavelet transform (CWT). The proposed algorithm was evaluated on the CSE database. The QRS detector obtained a sensitivity of Se = 99.19 % and the T wave detector attained a sensitivity of Se = 98.37 %. Standard deviations of differences between program results and database annotations were computed for the QRS onset, the QRS end and the T wave end. Calculated standard deviations were smaller than given accepted tolerances.
Klíčová slova
ECG delineation, continuous wavelet transform, QRS detection, CSE standard database
Autoři
VÍTEK, M.; KOZUMPLÍK, J.
Rok RIV
2008
Vydáno
24. 4. 2008
Nakladatel
Ing. Zdeněk Novotný CSc., Ondráčkova 105, Brno
ISBN
978-80-214-3617-6
Kniha
PROCEEDINGS OF THE 14th CONFERENCE STUDENT EEICT 2008 VOLUME 4
Číslo edice
1
Strany od
285
Strany do
289
Strany počet
5
BibTex
@inproceedings{BUT26143, author="Martin {Vítek} and Jiří {Kozumplík}", title="DETECTION OF QRS BOUNDARIES AND T WAVE END IN MULTILEAD ECG SIGNALS", booktitle="PROCEEDINGS OF THE 14th CONFERENCE STUDENT EEICT 2008 VOLUME 4", year="2008", number="1", pages="285--289", publisher="Ing. Zdeněk Novotný CSc., Ondráčkova 105, Brno", isbn="978-80-214-3617-6" }