Detail publikace

Generation and detection of hyperpolarized xenon

BUCHTA, Z. RYCHNOVSKÝ, J. LAZAR, J. STARČUK, Z.

Originální název

Generation and detection of hyperpolarized xenon

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

We present the experimental results of generation and of detection of hyperpolarized xenon obtained by 4.7 T, 200 MHz magnetic resonance (MR) system Xenon 129 was hyperpolarized by the spin-exchange with Rubidium pumped first by Ti:Sa laser and also by extended cavity laser system based on a high-power laser diode optimized for maximum efficiency of the optical pumping process. The application of the arrangement with semiconductor laser system is oriented medicine, especially to continuous production of hyperpolarized Xenon (HpXe) which serves as an contrast media in MR imaging systems.

Klíčová slova

extended cavity laser system, Ti:Sa laser, hyperpolarized xenon,

Autoři

BUCHTA, Z.; RYCHNOVSKÝ, J.; LAZAR, J.; STARČUK, Z.

Rok RIV

2007

Vydáno

26. 9. 2007

ISBN

978-1-4244-0987-7

Kniha

Proceedings of the conference IEEE Africon 2007

Strany od

286.1

Strany do

286.4

Strany počet

4

BibTex

@inproceedings{BUT28401,
  author="Zdeněk {Buchta} and Jan {Rychnovský} and Josef {Lazar} and Zenon {Starčuk}",
  title="Generation and detection of hyperpolarized xenon",
  booktitle="Proceedings of the conference IEEE Africon 2007",
  year="2007",
  pages="286.1--286.4",
  isbn="978-1-4244-0987-7"
}