Originální abstrakt

This article is aimed to compare of induction machine and synchronous machine with per-manent magnet. This compression is based on generalized sizing equation. Comparison will be sized of machine - diameter of air gap and length. For comparison, we will suppose, that both type of machine have the same efficiency and output power. In this article there is calculated only with sizing equation and there isn't calculated with another aspect of de-sign of electrical machine.

Klíčová slova

permenanet magnet synchronous machine, induction machine, sizing equation