HUZLÍK, R.
Originální název
COMPARISON OF PMSM AND INDUCTION MACHINE BASED ON GENERALIZED SIZING EQUATION
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
This article is aimed to compare of induction machine and synchronous machine with per-manent magnet. This compression is based on generalized sizing equation. Comparison will be sized of machine - diameter of air gap and length. For comparison, we will suppose, that both type of machine have the same efficiency and output power. In this article there is calculated only with sizing equation and there isn't calculated with another aspect of de-sign of electrical machine.
Klíčová slova
permenanet magnet synchronous machine, induction machine, sizing equation
Autoři
Rok RIV
2009
Vydáno
23. 4. 2009
Nakladatel
NOVPRESS s.r.o
Místo
Brno
ISBN
978-80-214-3869-9
Kniha
Proceedings of the 15th conference Student EEICT 2009 - volume 3
Strany od
78
Strany do
81
Strany počet
4
BibTex
@inproceedings{BUT33490, author="Rostislav {Huzlík}", title="COMPARISON OF PMSM AND INDUCTION MACHINE BASED ON GENERALIZED SIZING EQUATION", booktitle="Proceedings of the 15th conference Student EEICT 2009 - volume 3", year="2009", pages="78--81", publisher="NOVPRESS s.r.o", address="Brno", isbn="978-80-214-3869-9" }