FRANK, V. HANN, D. STRAŽIŠAR, J. SVĚRÁK, T.
Originální název
Bulk properties of powders evaluated on Johanson Indicizer
Typ
abstrakt
Jazyk
angličtina
Originální abstrakt
While the Jenike cell is the basic instrumental device for the bulk properties measurement since the 50s of the last century already many newer systems of powders bulk properties measurement has appeared in the last 20 years mainly. One of the commercial most successful system in the area of the period is Johanson s Indicizer. The paper offers the comparison of the Jenike cell and Johanson s Indicizer bulk properties measurement data of both,the particle grain size stepped up series of powdered materials and the different surface active agent quantity of treatment of powdered materials series.
Klíčová slova
bulk properties, powdered materials, Johanson s Indicizer
Autoři
FRANK, V.; HANN, D.; STRAŽIŠAR, J.; SVĚRÁK, T.
Vydáno
27. 9. 2006
Nakladatel
Process Engineering Publisher
Místo
Praha
ISBN
80-86059-45-6
Edice
1
Strany od
881
Strany do
Strany počet
BibTex
@misc{BUT60384, author="Vítězslav {Frank} and Damjan {Hann} and Janez {Stražišar} and Tomáš {Svěrák}", title="Bulk properties of powders evaluated on Johanson Indicizer", year="2006", series="1", pages="881--881", publisher="Process Engineering Publisher", address="Praha", isbn="80-86059-45-6", note="abstract" }