ADÁMEK, J. JURÁNKOVÁ, V.
Originální název
Detection of Imperfection in Concrete Structure from Durability Viewpoint
Typ
abstrakt
Jazyk
angličtina
Originální abstrakt
From extensive measurements we have came to definite conclusion that by the determination of a coefficient kT with relevantly considered value of mass moisture, it is possible to qualify a state of a covercrete structure up to 50 mm. Sensitivity of the method is very high, which can be demonstrated e.g. by the results of control on a bridge segment made from self-compacted concrete. Concreting has run without a breaking. High imperfection of the concrete has been assumed; nevertheless the measurement of the coefficient kT has proved that the porous system and contingent imperfections at examined areas were not congruent.
Klíčová slova
TPT; Torrent; durability
Autoři
ADÁMEK, J.; JURÁNKOVÁ, V.
Vydáno
24. 5. 2010
Místo
Latvia
Strany od
20
Strany do
Strany počet
1
BibTex