Detail publikace

Detection of Eccentricity and Bearings Fault Using Stray Flux Monitoring

VÍTEK, O. JANDA, M. HÁJEK, V. BAUER, P.

Originální název

Detection of Eccentricity and Bearings Fault Using Stray Flux Monitoring

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

The article describes the possibilities of employment of external magnetic field for detection of rotor eccentricity and for bearing fault diagnosis. Proposed method uses the magnetic flux density in proximity of induction motor as a diagnostic signal and it reaches the relatively high sensitivity in case of rotating air gap asymmetry represented by dynamic eccentricity. Since the bearing fault is the most frequent type of failure, the feasibility of applying this method is investigated. The results of experimental tests are introduced, including the motors with dynamic eccentricity and with artificially damaged bearing on the inner race. Both the stray flux and stator current are measured and compared in frequency domain.

Klíčová slova

Ball bearings, Fault diagnosis, Fault detection, Induction motors

Autoři

VÍTEK, O.; JANDA, M.; HÁJEK, V.; BAUER, P.

Rok RIV

2011

Vydáno

6. 9. 2011

Nakladatel

IEEE

Místo

Bologna, IT

ISBN

978-1-4244-9302-9

Kniha

Proceedings of the 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives

Strany od

456

Strany do

461

Strany počet

6

URL

BibTex

@inproceedings{BUT72774,
  author="Ondřej {Vítek} and Marcel {Janda} and Vítězslav {Hájek} and Pavol {Bauer}",
  title="Detection of Eccentricity and Bearings Fault Using Stray Flux Monitoring",
  booktitle="Proceedings of the 8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics & Drives",
  year="2011",
  pages="456--461",
  publisher="IEEE",
  address="Bologna, IT",
  doi="10.1109/DEMPED.2011.6063663",
  isbn="978-1-4244-9302-9",
  url="http://ieeexplore.ieee.org"
}