Detail publikace

Laděný tlumič na visuté lávce

KIKA, O. KRATOCHVÍL, O.

Originální název

Laděný tlumič na visuté lávce

Anglický název

Tunned mass damper on the suspension footbridge

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

čeština

Originální abstrakt

The paper deals how to find the optimal parameters of tunned mass damper on the footbridge laden by wind. The finiteelement analysis model was prepared in the program system ANSYS . The wind load was applied according to European standard EN 1991-2-4. The maximum displacement during harmonic analysis was monitored and its value was reduced to a minimum by well-designed tunned mass damper.

Anglický abstrakt

The paper deals how to find the optimal parameters of tunned mass damper on the footbridge laden by wind. The finiteelement analysis model was prepared in the program system ANSYS . The wind load was applied according to European standard EN 1991-2-4. The maximum displacement during harmonic analysis was monitored and its value was reduced to a minimum by well-designed tunned mass damper.

Klíčová slova

Tunned mass damper, system ANSYS, finite element method, foodbridge, harmonic analysis

Klíčová slova v angličtině

Tunned mass damper, system ANSYS, finite element method, foodbridge, harmonic analysis

Autoři

KIKA, O.; KRATOCHVÍL, O.

Rok RIV

2011

Vydáno

4. 2. 2011

Místo

Brno

ISBN

978-80-214-4232-0

Kniha

Juniorstav 2011

Strany od

219

Strany do

222

Strany počet

4

BibTex

@inproceedings{BUT89968,
  author="Ondřej {Kika} and Ondřej {Kratochvíl}",
  title="Laděný tlumič na visuté lávce",
  booktitle="Juniorstav 2011",
  year="2011",
  pages="219--222",
  address="Brno",
  isbn="978-80-214-4232-0"
}