Detail publikace

Bone tissue surface reconstruction and analysis from Swept Source OCT images

ČMIEL, V. KUNA, Z. SEKORA, J. BALOGH, J. PROVAZNÍK, I.

Originální název

Bone tissue surface reconstruction and analysis from Swept Source OCT images

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

In our study Swept Source OCT images were used to bone tissue surface reconstruction and analysis. Image processing was used to find object bor-ders with the air in each OCT slide. The tissue surface was reconstructed using Marching Cubes algorithm. Following surface analysis was made from extracted image borders. Least squares method between located border and polynomials up to 50th order was tested.

Klíčová slova

oct, swept source, reconstruction, visualization

Klíčová slova v angličtině

oct, swept source, reconstruction, visualization

Autoři

ČMIEL, V.; KUNA, Z.; SEKORA, J.; BALOGH, J.; PROVAZNÍK, I.

Rok RIV

2012

Vydáno

14. 7. 2012

Místo

Řecko

ISBN

978-618-5009-04-5

Kniha

PROCEEDINGS of the 10th International Conference on INFORMATION COMMUNICATION TECHNOLOGIES IN HEALTH

Strany od

291

Strany do

298

Strany počet

7

BibTex

@inproceedings{BUT92776,
  author="Vratislav {Čmiel} and Zdeněk {Kuna} and Jiří {Sekora} and Jaroslav {Balogh} and Valentine {Provazník}",
  title="Bone tissue surface reconstruction and analysis from Swept Source OCT images",
  booktitle="PROCEEDINGS of the 10th International Conference on INFORMATION COMMUNICATION TECHNOLOGIES IN HEALTH",
  year="2012",
  pages="291--298",
  address="Řecko",
  isbn="978-618-5009-04-5"
}