Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
URBANOVÁ, L. BLAŽEK-FIALOVÁ, I. SRNEC, R. PĚNČÍK, J. KRŠEK, P. NEČAS, A.
Originální název
Mathematical model of mechanical testing of bone-implant (4.5 mm LCP) construct
Typ
článek v časopise - ostatní, Jost
Jazyk
angličtina
Originální abstrakt
The study deals with the possibility of substituting time- and material-demanding mechanical testing of a bone defect fixation by mathematical modelling. Based on the mechanical model, a mathematical model of bone-implant construct stabilizing experimental segmental femoral bone defect (segmental ostectomy) in a miniature pig ex vivo model using 4.5 mm titanium LCP was created. It was subsequently computer-loaded by forces acting parallel to the long axis of the construct. By the effect of the acting forces the displacement vector sum of individual construct points occurred. The greatest displacement was noted in the end segments of the bone in close proximity to ostectomy and in the area of the empty central plate hole (without screw) at the level of the segmental bone defect. By studying the equivalent von Mises stress SIGMAeqv on LCP as part of the tested construct we found that the greatest changes of stress occur in the place of the empty central plate hole. The distribution of this strain was relatively symmetrical along both sides of the hole. The exceeding of the yield stress value and irreversible plastic deformations in this segment of LCP occurred at the acting of the force of 360 N. These findings are in line with the character of damage of the same construct loaded during its mechanic testing. We succeeded in creating a mathematical model of the bone-implant construct which may be further used for computer modelling of real loading of similar constructs chosen for fixation of bone defects in both experimental and clinical practice.
Klíčová slova
Fracture fixation, implant failure, material deformation, yield stress, displacement vector sum.
Autoři
URBANOVÁ, L.; BLAŽEK-FIALOVÁ, I.; SRNEC, R.; PĚNČÍK, J.; KRŠEK, P.; NEČAS, A.
Rok RIV
2012
Vydáno
17. 9. 2012
Nakladatel
University of Veterinary and Pharmaceutical Sciences in Brno
Místo
Brno, Czech Republic
ISSN
0001-7213
Periodikum
ACTA VETERINARIA BRNO
Ročník
81
Číslo
2
Stát
Česká republika
Strany od
211
Strany do
215
Strany počet
5
URL
https://actavet.vfu.cz/81/2/0211/
Plný text v Digitální knihovně
http://hdl.handle.net/11012/102750
BibTex
@article{BUT93877, author="Lucie {Urbanová} and Iva {Blažek-Fialová} and Robert {Srnec} and Jan {Pěnčík} and Přemysl {Kršek} and Alois {Nečas}", title="Mathematical model of mechanical testing of bone-implant (4.5 mm LCP) construct", journal="ACTA VETERINARIA BRNO", year="2012", volume="81", number="2", pages="211--215", doi="10.2754/avb201281020211", issn="0001-7213", url="https://actavet.vfu.cz/81/2/0211/" }