Detail publikace
Micromachined Hydrogen Sensors with Nanostructured Tungsten Oxide Active Layers: Nanodots vs Nanotubes. A Comparative Study
VAZQUEZ, R. CALAVIA, R. CORREIG, X. VILANOVA, X. LLOBET, E. MOZALEV, A.
Originální název
Micromachined Hydrogen Sensors with Nanostructured Tungsten Oxide Active Layers: Nanodots vs Nanotubes. A Comparative Study
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
In this work we present the preparation of two types of metal-oxide gas sensors on the MEMS-based platforms with substantially enlarged surface-to-volume ratios - porous-alumina-assisted tungsten oxide nanodot film and porous-anodic-alumina-supported nanotubular tungsten oxide layer - and report on the comparative analysis of their properties for hydrogen detection
Klíčová slova
microsensors, microhotplate, porous anodic alumina, tingsten trioxide
Autoři
VAZQUEZ, R.; CALAVIA, R.; CORREIG, X.; VILANOVA, X.; LLOBET, E.; MOZALEV, A.
Rok RIV
2012
Vydáno
31. 10. 2012
Nakladatel
Tanger ltd
Místo
Ketlickova 62, Slezska, Ostrava 710 00, Czech Republic
ISBN
978-80-87294-27-7
Kniha
4th International Conference on NANOCON
Strany od
1
Strany do
6
Strany počet
6
BibTex
@inproceedings{BUT96823,
author="Rosa Maria {Vazquez} and Raul {Calavia} and Xavier {Correig} and Xavier {Vilanova} and Eduard {Llobet} and Alexander {Mozalev}",
title="Micromachined Hydrogen Sensors with Nanostructured Tungsten Oxide Active Layers: Nanodots vs Nanotubes. A Comparative Study",
booktitle="4th International Conference on NANOCON",
year="2012",
pages="1--6",
publisher="Tanger ltd",
address="Ketlickova 62, Slezska, Ostrava 710 00, Czech Republic",
isbn="978-80-87294-27-7"
}