Detail publikace

Micromachined Hydrogen Sensors with Nanostructured Tungsten Oxide Active Layers: Nanodots vs Nanotubes. A Comparative Study

VAZQUEZ, R. CALAVIA, R. CORREIG, X. VILANOVA, X. LLOBET, E. MOZALEV, A.

Originální název

Micromachined Hydrogen Sensors with Nanostructured Tungsten Oxide Active Layers: Nanodots vs Nanotubes. A Comparative Study

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

In this work we present the preparation of two types of metal-oxide gas sensors on the MEMS-based platforms with substantially enlarged surface-to-volume ratios - porous-alumina-assisted tungsten oxide nanodot film and porous-anodic-alumina-supported nanotubular tungsten oxide layer - and report on the comparative analysis of their properties for hydrogen detection

Klíčová slova

microsensors, microhotplate, porous anodic alumina, tingsten trioxide

Autoři

VAZQUEZ, R.; CALAVIA, R.; CORREIG, X.; VILANOVA, X.; LLOBET, E.; MOZALEV, A.

Rok RIV

2012

Vydáno

31. 10. 2012

Nakladatel

Tanger ltd

Místo

Ketlickova 62, Slezska, Ostrava 710 00, Czech Republic

ISBN

978-80-87294-27-7

Kniha

4th International Conference on NANOCON

Strany od

1

Strany do

6

Strany počet

6

BibTex

@inproceedings{BUT96823,
  author="Rosa Maria {Vazquez} and Raul {Calavia} and Xavier {Correig} and Xavier {Vilanova} and Eduard {Llobet} and Alexander {Mozalev}",
  title="Micromachined Hydrogen Sensors with Nanostructured Tungsten Oxide Active Layers: Nanodots vs Nanotubes. A Comparative Study",
  booktitle="4th International Conference on NANOCON",
  year="2012",
  pages="1--6",
  publisher="Tanger ltd",
  address="Ketlickova 62, Slezska, Ostrava 710 00, Czech Republic",
  isbn="978-80-87294-27-7"
}