Detail publikace

Solution of thermal bridge under the opening in the cladding by means of support structure for a doors threshold made of thermal insulation composite material support structure for a doors threshold made of thermal insulation Solution of thermal bridge under the opening in the cladding by means of support structure for a doors threshold made of thermal insulation composite material

POSPÍŠIL, T. PĚNČÍK, J. MATĚJKA, L. MATĚJKA, L. KALUŽOVÁ, A. DOSTÁLOVÁ, D.

Originální název

Solution of thermal bridge under the opening in the cladding by means of support structure for a doors threshold made of thermal insulation composite material support structure for a doors threshold made of thermal insulation Solution of thermal bridge under the opening in the cladding by means of support structure for a doors threshold made of thermal insulation composite material

Typ

článek v časopise - ostatní, Jost

Jazyk

angličtina

Originální abstrakt

In the process of sustainable construction is the emphasis placed on saving energy, reducing use of natural resources, increase the life cycle of materials by recycling, etc. Rising energy prices put increasing emphasis of builders and investors to better solution of thermal bridges. Solution can be done using a conventional materials, but also advanced materials meet the requirement of a sustainable construction and a reducing consumption of natural resources and extending of the life cycle of material. An example of such material is the thermal insulation composite material. This new developed material with low coefficient of thermal conductivity below the value of 0.100 W/mK is made of recycled waste polymer and recycled filler in the form of granules from recycled glass. In the paper are compared two variants of solution of thermal bridge under the opening in the cladding. In the first variant a wooden door opening in the perimetral cladding is deposited on a support structure for a doors threshold made of a thermal insulation composite material. In the second variant is used a lower shaped brick block. The variants of different foundation of a wooden door opening are compared in terms of a lowest surface temperature and of a temperature factor of the inner surface fRsi and its critical value fRsi,cr according to ČSN 73 0540-2 and ČSN EN ISO 10211.

Klíčová slova

Composite, Elimination, Energy Saving, Heat Loss, Polymers, Thermal Bridge, Waste

Autoři

POSPÍŠIL, T.; PĚNČÍK, J.; MATĚJKA, L.; MATĚJKA, L.; KALUŽOVÁ, A.; DOSTÁLOVÁ, D.

Rok RIV

2013

Vydáno

1. 1. 2013

Nakladatel

Trans Tech Publications

Místo

Switzerland

ISSN

1013-9826

Periodikum

Key Engineering Materials (print)

Ročník

531-532

Číslo

2013

Stát

Švýcarská konfederace

Strany od

404

Strany do

408

Strany počet

5

BibTex

@article{BUT97439,
  author="Tomáš {Pospíšil} and Jan {Pěnčík} and Libor {Matějka} and Libor {Matějka} and Alena {Kalužová} and Darina {Dostálová}",
  title="Solution of thermal bridge under the opening in the cladding by means of support structure for a doors threshold made of thermal insulation composite material support structure for a doors threshold made of thermal insulation Solution of thermal bridge under the opening in the cladding by means of support structure for a doors threshold made of thermal insulation composite material",
  journal="Key Engineering Materials (print)",
  year="2013",
  volume="531-532",
  number="2013",
  pages="404--408",
  issn="1013-9826"
}