Detail publikace

New Technologies for Individual Joint Implants

PÍŠKA, M. SEDLÁK, J. PEKÁRKOVÁ, E.

Originální název

New Technologies for Individual Joint Implants

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

The paper deals with a technology of processing CT data of the knee joint and production of implants that substitutes only the defected bone part, minimizes the removal origin bone and guarantees a better fitting and function of the implant, especially the knee one. The new high-technology is focused on distal part of femur and production of the most important part - the femoral component. The technology is split in three main steps – a production of the optimal implant and an insertion of the implant onto the origin bone.

Klíčová slova

Joint, Implant, Technology, CAD software, CT data

Autoři

PÍŠKA, M.; SEDLÁK, J.; PEKÁRKOVÁ, E.

Rok RIV

2013

Vydáno

27. 10. 2013

Nakladatel

Universitetsservice US AB

Místo

Stockholm, Sweden

ISBN

978-91-7501-893-5

Kniha

Proceedings of the International Conference on Advanced Manufacturing Engineering and Technologies, NEWTECH 2013

Číslo edice

2

Strany od

263

Strany do

272

Strany počet

10

BibTex

@inproceedings{BUT102364,
  author="Miroslav {Píška} and Josef {Sedlák} and Eva {Pekárková}",
  title="New Technologies for Individual Joint Implants",
  booktitle="Proceedings of the International Conference on Advanced Manufacturing Engineering and Technologies, NEWTECH 2013",
  year="2013",
  number="2",
  pages="263--272",
  publisher="Universitetsservice US AB",
  address="Stockholm, Sweden",
  isbn="978-91-7501-893-5"
}