Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
NEUŽIL, P. SUN, W. KARÁSEK, T. MANZ, A.
Originální název
Nanoliter-sized overheated reactor
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
We report on a microfluidic system formed by 200 nl water droplets, encapsulated by a 600 nl mineral oil placed on a hydrophobically coated glass microscope cover slip. The micromachined heater underneath the glass was able to heat up the sample at a heating rate of 650 C/s, heating the water sample up to 200 C in less than 2 s. The sample/glass and the sample/oil interface did not have nucleation centers, showing that the sample reached a superheated stage without the necessity of being pressurized to suppress boiling. This method can be utilized for various applications currently being conducted in autoclaves.
Klíčová slova
nanoliter, overheated, reactor
Autoři
NEUŽIL, P.; SUN, W.; KARÁSEK, T.; MANZ, A.
Rok RIV
2015
Vydáno
16. 1. 2015
Nakladatel
AIP Publishing
ISSN
0003-6951
Periodikum
Applied Physics Letters
Ročník
106
Číslo
024104
Stát
Spojené státy americké
Strany od
024104-1
Strany do
024104-5
Strany počet
5
URL
http://scitation.aip.org/content/aip/journal/apl/106/2/10.1063/1.4905851
Plný text v Digitální knihovně
http://hdl.handle.net/11012/61764