Originální název
Autonomous Monitoring Unit of Fault Condition with Vibration Energy Harvester
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
This paper deals with a proposal of an autonomousmonitoring unit of vibration overload. This autonomous unit will be used for a monitoring of the motor-generator system in our lab. There was an accident of the tested system in the past and the connection shaft was destroyed due to an unsuitable overloading of the tested system. Several hours before accident the significant mechanical vibrations were observed. This emergency operation could damage other parts of motor-generator system in our lab. Main idea of our development is design of autonomous monitoring unit for alerting of overload operations with significant mechanical vibrations. The energy harvesting method can be used for autonomous powering of this monitoring unit and wireless vibration sensor is connected. The signal of an overloading condition is transmitted to the control panel.
Klíčová slova
monitoring; energy harvesting; vibration; power management; battery; wireless sensor module;
Autoři
VETIŠKA, V.; HADAŠ, Z.; HYNČICA, O.; ONDRŮŠEK, Č.
Rok RIV
2015
Vydáno
10. 6. 2015
Místo
Řím
ISBN
978-1-4799-7993-6
Kniha
Environment and Electrical Engineering (EEEIC), 2015 IEEE 15th International Conference on
Strany od
980
Strany do
985
Strany počet
6
URL
https://ieeexplore.ieee.org/document/7165297
BibTex
@inproceedings{BUT117873, author="Vojtěch {Vetiška} and Ondřej {Hynčica} and Čestmír {Ondrůšek} and Zdeněk {Hadaš}", title="Autonomous Monitoring Unit of Fault Condition with Vibration Energy Harvester", booktitle="Environment and Electrical Engineering (EEEIC), 2015 IEEE 15th International Conference on", year="2015", pages="980--985", address="Řím", doi="10.1109/EEEIC.2015.7165297", isbn="978-1-4799-7993-6", url="https://ieeexplore.ieee.org/document/7165297" }