Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
DOSTÁL, Z. SLABÝ, T. KVASNICA, L. LOŠŤÁK, M. KŘÍŽOVÁ, A. CHMELÍK, R.
Originální název
Automated alignment method for coherence-controlled holographic microscope
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Coherence-controlled holographic microscope (CCHM) was developed particularly for quantitative phase imaging and measurement of live cell dynamics, which is the proper subject of digital holographic microscopy (DHM). CCHM in low-coherence mode extends DHM in the study of living cells. However, this advantage is compensated by sensitivity of the system to easily become misaligned, which is a serious hindrance to wanted performance. Therefore, it became clear that introduction of a self-correcting system is inevitable. Accordingly, we had to devise a theory of a suitable control and design an automated alignment system for CCHM. The modulus of the reconstructed holographic signal was identified as a significant variable for guiding the alignment procedures. From this, we derived the original basic realignment three-dimensional algorithm, which encompasses a unique set of procedures for automated alignment that contains processes for initial and advanced alignment as well as long-term maintenance of microscope tuning. All of these procedures were applied to a functioning microscope and the tested processes were successfully validated. Finally, in such a way, CCHM is enabled to substantially contribute to study of biology, particularly of cancer cells in vitro.
Klíčová slova
holographic microscopy; quantitative phase imaging; automated alignment; holographic signal
Autoři
DOSTÁL, Z.; SLABÝ, T.; KVASNICA, L.; LOŠŤÁK, M.; KŘÍŽOVÁ, A.; CHMELÍK, R.
Rok RIV
2015
Vydáno
28. 10. 2015
Nakladatel
SPIE
ISSN
1083-3668
Periodikum
JOURNAL OF BIOMEDICAL OPTICS
Ročník
20
Číslo
11
Stát
Spojené státy americké
Strany od
1
Strany do
8
Strany počet
URL
https://www.spiedigitallibrary.org/journals/Journal-of-Biomedical-Optics/volume-20/issue-11/111215/Automated-alignment-method-for-coherence-controlled-holographic-microscope/10.1117/1.JBO.20.11.111215.full
Plný text v Digitální knihovně
http://hdl.handle.net/11012/194979
BibTex
@article{BUT117913, author="Zbyněk {Dostál} and Tomáš {Slabý} and Lukáš {Kvasnica} and Martin {Lošťák} and Aneta {Křížová} and Radim {Chmelík}", title="Automated alignment method for coherence-controlled holographic microscope", journal="JOURNAL OF BIOMEDICAL OPTICS", year="2015", volume="20", number="11", pages="1--8", doi="10.1117/1.JBO.20.11.111215", issn="1083-3668", url="https://www.spiedigitallibrary.org/journals/Journal-of-Biomedical-Optics/volume-20/issue-11/111215/Automated-alignment-method-for-coherence-controlled-holographic-microscope/10.1117/1.JBO.20.11.111215.full" }