Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
VYROUBAL, P. KAZDA, T. BAČA, P.
Originální název
Finite Element Approach of Current Density Distribution in Lead Acid Battery Grid
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
In a lead-acid cell the active materials there are lead dioxide (PbO2) in the positive plate, sponge lead (Pb) in the negative plate, and a solution of sulphuric acid (H2SO4) in water as the electrolyte. A chemical reaction proceeds place between lead plates and sulphuric acid, producing electric current. When the charge is depleted, the battery can be recharged many times. This article deals with optimization of the shape of lead acid battery grid by discharging process using numerical simulation.
Klíčová slova
Lead Acid Battery, current density, grid
Autoři
VYROUBAL, P.; KAZDA, T.; BAČA, P.
Vydáno
12. 12. 2016
ISBN
978-80-214-5109-4
Kniha
ECS Transactions
Číslo edice
74
ISSN
1938-5862
Periodikum
Stát
Spojené státy americké
Strany od
63
Strany do
69
Strany počet
7
BibTex
@inproceedings{BUT129453, author="Petr {Vyroubal} and Tomáš {Kazda} and Petr {Bača}", title="Finite Element Approach of Current Density Distribution in Lead Acid Battery Grid", booktitle="ECS Transactions", year="2016", journal="ECS Transactions", number="74", pages="63--69", doi="10.1149/07401.0063ecst", isbn="978-80-214-5109-4", issn="1938-5862" }