Detail publikace

Design and testing of magnetorheological valve with fast force response time and great dynamic force range

KUBÍK, M. MACHÁČEK, O. ROUPEC, J. STRECKER, Z. MAZŮREK, I.

Originální název

Design and testing of magnetorheological valve with fast force response time and great dynamic force range

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

The paper deals with design, simulation and experimental testing of a magnetorheological (MR) valve with short response time. The short response time is achieved by a suitable design of an active zone in combination with use of a ferrite material for magnetic circuit. The magneto-static model and the simplified hydraulic model of the MR valve are examined and experimentally verified. The development the MR valve achieves an average response time 4.1 ms and the maximum dynamic force range of eight.

Klíčová slova

MR fluid, magnetorheological fluid, MR damper, magnetorheological damper

Autoři

KUBÍK, M.; MACHÁČEK, O.; ROUPEC, J.; STRECKER, Z.; MAZŮREK, I.

Vydáno

7. 3. 2017

ISSN

0964-1726

Periodikum

SMART MATERIALS & STRUCTURES

Ročník

26

Číslo

4

Stát

Spojené království Velké Británie a Severního Irska

Strany od

1

Strany do

10

Strany počet

10

URL

BibTex

@article{BUT134153,
  author="Michal {Kubík} and Ondřej {Macháček} and Jakub {Roupec} and Zbyněk {Strecker} and Ivan {Mazůrek}",
  title="Design and testing of magnetorheological valve with fast force response time and great dynamic force range",
  journal="SMART MATERIALS & STRUCTURES",
  year="2017",
  volume="26",
  number="4",
  pages="1--10",
  doi="10.1088/1361-665X/aa6066",
  issn="0964-1726",
  url="http://iopscience.iop.org/article/10.1088/1361-665X/aa6066/pdf"
}