The paper deals with design, simulation and experimental testing of a magnetorheological (MR) valve with short response time. The short response time is achieved by a suitable design of an active zone in combination with use of a ferrite material for magnetic circuit. The magneto-static model and the simplified hydraulic model of the MR valve are examined and experimentally verified. The development the MR valve achieves an average response time 4.1 ms and the maximum dynamic force range of eight.
Klíčová slova
MR fluid, magnetorheological fluid, MR damper, magnetorheological damper
Autoři
KUBÍK, M.; MACHÁČEK, O.; ROUPEC, J.; STRECKER, Z.; MAZŮREK, I.
Vydáno
7. 3. 2017
ISSN
0964-1726
Periodikum
SMART MATERIALS & STRUCTURES
Ročník
26
Číslo
4
Stát
Spojené království Velké Británie a Severního Irska
Strany od
1
Strany do
10
Strany počet
URL
http://iopscience.iop.org/article/10.1088/1361-665X/aa6066/pdf
BibTex
@article{BUT134153, author="Michal {Kubík} and Ondřej {Macháček} and Jakub {Roupec} and Zbyněk {Strecker} and Ivan {Mazůrek}", title="Design and testing of magnetorheological valve with fast force response time and great dynamic force range", journal="SMART MATERIALS & STRUCTURES", year="2017", volume="26", number="4", pages="1--10", doi="10.1088/1361-665X/aa6066", issn="0964-1726", url="http://iopscience.iop.org/article/10.1088/1361-665X/aa6066/pdf" }