Detail publikace

Long-action of additional horizontal prestressing on masonry

PĚKNÍK, R. KLUSÁČEK, L.

Originální název

Long-action of additional horizontal prestressing on masonry

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

This article is focused on verifying behaviour of a brick masonry which was horizontally post-tensioned. An experimental model of three walls has been built for the measurement. The model is in scale 1:1 and represents a part of a real structure. Longitudinal strain of brick walls has been measured by wire strain gauges in important places. Surrounding temperature and temperature inside the walls were also recorded. Results of the experiment have been continuously evaluated and compared with the simplified numerical models. Right now we have a better picture of actual behaviour of the brick masonry wall which was horizontally prestressed and we are able to design appropriate restoration works for historical buildings.

Klíčová slova

addition prestressing; strain; brick walls; experimental measurement

Autoři

PĚKNÍK, R.; KLUSÁČEK, L.

Vydáno

20. 7. 2017

Nakladatel

Elsevier

ISSN

1877-7058

Periodikum

Procedia Engineering

Ročník

195

Číslo

1

Stát

Nizozemsko

Strany od

67

Strany do

72

Strany počet

6

URL

Plný text v Digitální knihovně

BibTex

@article{BUT138041,
  author="Robin {Pěkník} and Ladislav {Klusáček}",
  title="Long-action of additional horizontal prestressing on masonry",
  journal="Procedia Engineering",
  year="2017",
  volume="195",
  number="1",
  pages="67--72",
  doi="10.1016/j.proeng.2017.04.525",
  issn="1877-7058",
  url="https://www.sciencedirect.com/science/article/pii/S1877705817320775"
}