Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
PETROSYAN, T. SUK, L. KATOVSKÝ, K.
Originální název
Analysis of passive heat removal system through steam generator by ANSYS fluent
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
This paper presents the simulation of the condensation of water vapor in one tube of heat exchanger in Passive Heat Removal System, which is a protective safety system of the Nuclear Power Plant. The simulation accounts for the two-phase turbulent flow of the water vapor along the tube with an assumption of constant wall temperature. The results from the CFD (Computational Fluid Dynamics) simulations are compared with the experimental results from the literature for the condensation of water vapor for inlet velocities of 1 m/s and 3 m/s, as well as with the result of simulation analyzed by other software.
Klíčová slova
Condensation; Steam Generator; ANSYS; Passive Heat Removal; Nuclear Safety
Autoři
PETROSYAN, T.; SUK, L.; KATOVSKÝ, K.
Vydáno
22. 10. 2019
Nakladatel
American Institute of Physics Inc.
Místo
AIP College Park Maryland, USA
ISBN
978-0-7354-1908-7
Kniha
AIP Conference Proceedings, Volume 2163, 23rd International Scientific Conference of Young Scientists and Specialists, AYSS 2019
ISSN
0094-243X
Periodikum
AIP conference proceedings
Ročník
2163
Číslo
060002
Stát
Spojené státy americké
Strany od
060002-1
Strany do
060002-5
Strany počet
5