Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
KALASOVÁ, D. BŘÍNEK, A. ŠLOUF, M. DUŠKOVÁ - SMRČKOVÁ, M. ZIKMUND, T. PATÁKOVÁ, Z. KAISER, J.
Originální název
Wide-Cone Angle Phase-Contrast X-Ray Computed Tomography of Synthetic Polymer Materials
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
X-ray phase-contrast imaging (PCI) is sensitive to the phase shift of X-rays induced by the sample. This is advantageous for low X-ray absorption samples, such as polymers, biomaterials, tissues, and scaffolds. We show propagation-based phase-contrast X-ray computed tomography (CT) imaging [propagation-based imaging (PBI)] in a specific configuration with the wide-cone angle (>50 degrees), polychromatic X-ray source, and a flat-panel detector. We demonstrate PBI on measurements with a polymer composite. The experiments show a tradeoff between high signal-to-noise ratio (SNR) acquisition at very large cone angles and low-SNR acquisition at large propagation distances. The degree of data quality improvement by phase retrieval increases for high propagation distances. We show the application of PBI on macroporous synthetic hydrogels, which represents an important type of material with a complex 3-D morphology in the field of polymer science. With the use of the above-described experimental configuration, it is possible to visualize the hydrogels and segment the structure of the sample in tomographic data. The segmented sample can be used for morphology characterization, such as the description of internal space or determination of specific surface area (SSA).
Klíčová slova
X-ray imaging; Polymers; Computed tomography; Scanning electron microscopy; Detectors; Phase-contrast imaging (PCI); propagation based imaging (PBI); synthetic polymer materials; wide-cone angle X-ray computed tomography (CT); X-ray CT
Autoři
KALASOVÁ, D.; BŘÍNEK, A.; ŠLOUF, M.; DUŠKOVÁ - SMRČKOVÁ, M.; ZIKMUND, T.; PATÁKOVÁ, Z.; KAISER, J.
Vydáno
1. 11. 2020
Nakladatel
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Místo
PISCATAWAY
ISSN
0018-9456
Periodikum
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Ročník
69
Číslo
11
Stát
Spojené státy americké
Strany od
8910
Strany do
8918
Strany počet
9
URL
https://ieeexplore.ieee.org/document/9094587
BibTex
@article{BUT165958, author="Dominika {Kalasová} and Adam {Břínek} and Miroslav {Šlouf} and Miroslava {Dušková - Smrčková} and Tomáš {Zikmund} and Zuzana {Patáková} and Jozef {Kaiser}", title="Wide-Cone Angle Phase-Contrast X-Ray Computed Tomography of Synthetic Polymer Materials", journal="IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT", year="2020", volume="69", number="11", pages="8910--8918", doi="10.1109/TIM.2020.2995232", issn="0018-9456", url="https://ieeexplore.ieee.org/document/9094587" }