HAMMER, M. VAVRUŠKA, J. LATINA, P.
Originální název
Determination of the Influence of Fuzzy Predictor Parameters in Lifetime Prediction of Insulating Material for Electrical Rotary Machines Windings
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
The contribution deals with the life prediction of the Relanex insulating material which is used for the insulation of electrical rotary machines. With the help of the Sugeno type fuzzy controller, we determined the quantity of breakdown voltage and, on the basis of the breakdown voltage, we determined the actual state of the insulating material in the light of disruptive strength. According to the measured matrix of particular input quantities (Bv : activation energy of the conductive effect, Ba : activation energy of the polarization effect, Uk : critical voltage) and consequential training phase, we can predict critical voltage values Ups, compare those values with real breakdown voltage Up and do evaluation with the help of the absolute and relative errors.
Klíčová slova
Insulating Material
Autoři
HAMMER, M.; VAVRUŠKA, J.; LATINA, P.
Vydáno
15. 6. 2004
Nakladatel
Hajnowka (Poland)
Místo
ISBN
83-917944-4-X
Kniha
XL International Symposium on Electrical Machines SME2004
Strany od
466
Strany do
469
Strany počet
4
BibTex
@inproceedings{BUT17282, author="Miloš {Hammer} and Jiří {Vavruška} and Petr {Latina}", title="Determination of the Influence of Fuzzy Predictor Parameters in Lifetime Prediction of Insulating Material for Electrical Rotary Machines Windings", booktitle="XL International Symposium on Electrical Machines SME2004", year="2004", pages="4", publisher="Hajnowka (Poland)", address="Hajnowka (Poland)", isbn="83-917944-4-X" }