Detail publikace

Impact of the Number of Measurements on Result Distortion

KUCHAŘÍK, J. ŠIMEK, A.

Originální název

Impact of the Number of Measurements on Result Distortion

Typ

článek ve sborníku mimo WoS a Scopus

Jazyk

angličtina

Originální abstrakt

This study investigates the distortion of results due to the number of corrosion current measurements. Samples were prepared by pressing and subsequently sintering iron and magnesium powders. The samples were then immersed in an SBL solution at 37 °C. Measurements took place over 23 days. For two samples, measurements were taken each time, while the remaining samples were measured in sequence on their respective days

Klíčová slova

corrosion, corrosion current, simulated body fluid, solution, oxidation

Autoři

KUCHAŘÍK, J.; ŠIMEK, A.

Vydáno

23. 4. 2024

Místo

Brno

ISBN

978-80-214-6231-1

Kniha

Proceedings I of the 30th Conference STUDENT EEICT 2024

Edice

1

Strany od

287

Strany do

292

Strany počet

6

URL

BibTex

@inproceedings{BUT189091,
  author="Jan {Kuchařík} and Antonín {Šimek}",
  title="Impact of the Number of Measurements on Result Distortion",
  booktitle="Proceedings I of the 30th Conference STUDENT EEICT 2024",
  year="2024",
  series="1",
  pages="287--292",
  address="Brno",
  isbn="978-80-214-6231-1",
  url="https://www.eeict.cz/eeict_download/archiv/sborniky/EEICT_2024_sbornik_1.pdf"
}