Detail publikace

Sensor for lowest flows measurement.

ADÁMEK, M. PRÁŠEK, J. MELICHAR, P. SZENDIUCH, I. JAKUBKA, L.

Originální název

Sensor for lowest flows measurement.

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

This work covers one of the possible variants of non-invasive low mass flow measurement of homogenous fluids or gases using the calorimetric method. The principle is based on measurement of the temperature difference caused by convection and conduction. The flowmeter can measure the flow in both directions. The advantage of presented solution is very high sensitivity in low flows, proportional output response to the flow rates in specific range and independence on operating position.

Klíčová slova

Sensor, low flows measurement, calorimetric method

Autoři

ADÁMEK, M.; PRÁŠEK, J.; MELICHAR, P.; SZENDIUCH, I.; JAKUBKA, L.

Rok RIV

2005

Vydáno

19. 5. 2005

Nakladatel

Institute of Sensor and Actuator Systems, Vienna University of Technology

Místo

Wiener Neustadt, Austria

ISBN

0-7803-9325-2

Kniha

Proceedings of ISSE 2005

Číslo edice

1

Strany od

29

Strany do

33

Strany počet

5

BibTex

@inproceedings{BUT20935,
  author="Martin {Adámek} and Jan {Prášek} and Petr {Melichar} and Ivan {Szendiuch} and Luboš {Jakubka}",
  title="Sensor for lowest flows measurement.",
  booktitle="Proceedings of ISSE 2005",
  year="2005",
  volume="1",
  number="1",
  pages="29--33",
  publisher="Institute of Sensor and Actuator Systems, Vienna University of Technology",
  address="Wiener Neustadt, Austria",
  isbn="0-7803-9325-2"
}