Originální název
Methods for HP EM pulse measurement
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occured by the development of high power microwave pulse generator [1]. Applicable methods are presented in this paper. The method utilizing Faradays induction law allows the measurement of generated current. For the same purpose the magneto-optic method can be utilized, with its advantages. For measurement of output microwave pulse of the generator, the calorimetric method was designed and realized.
Klíčová slova
HPEM, EMP, magneto-otic effet, rogowski coil, calorimetric sensor
Autoři
DREXLER, P.; FIALA, P.
Rok RIV
2007
Vydáno
1. 8. 2007
Nakladatel
IWD
ISBN
1-4244-1276-5
Kniha
2007 International Waveform Diversity and Design Conference
Edice
1
Číslo edice
Strany od
28
Strany do
31
Strany počet
4
BibTex