Originální abstrakt
The contact resistance and linearity of VA charakteristic determine a relay quality. Electric current transport through relay contacts can be considered as a charge transport by metal-insulator-metal (MIM) structure. When electric field is applied the current transport is mainly due to tunnelling and thermionic emission. For very low I-layer thickness ballistics transport can be also dominant. When gold plating contacts are made, I-layer thickness can be so small, that VA characteristic is strictly linear and third harmonic voltage is negligible.
Klíčová slova v angličtině
third harmonic, linearity of VA characteristic, current transport