Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
GRMELA, L., PAVELKA, J., HLÁVKA, J.
Originální název
Relay contacts quality screening by non-linearity tester
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
The contact resistance and linearity of VA charakteristic determine a relay quality. Electric current transport through relay contacts can be considered as a charge transport by metal-insulator-metal (MIM) structure. When electric field is applied the current transport is mainly due to tunnelling and thermionic emission. For very low I-layer thickness ballistics transport can be also dominant. When gold plating contacts are made, I-layer thickness can be so small, that VA characteristic is strictly linear and third harmonic voltage is negligible.
Klíčová slova v angličtině
third harmonic, linearity of VA characteristic, current transport
Autoři
Vydáno
13. 9. 2001
Nakladatel
VUT v Brně
Místo
Brno
ISBN
80-214-1960-1
Kniha
Electronic Devices and Systems
Strany od
55
Strany do
Strany počet
1
BibTex