Detail publikace

Rigid olecranon fixation: A comparison of two techniques

PÍŠKA, M.

Originální název

Rigid olecranon fixation: A comparison of two techniques

Typ

článek v časopise - ostatní, Jost

Jazyk

angličtina

Originální abstrakt

A new fixation with threaded Medin K wires has been compared with standard AO technique for a two twist TBW. Thawed fresh frozen human elbow joints were used for this study. The gap distraction increased when a moment was applied and almost returned to its previous state when the moment was removed due to visco-elastic behaviour of the ligament. Early gap opening seems to be a featur of the TBW when loaded. The new technique of two partially threaded K wires may compete with the fixation of the two twist TBW under these clinical conditions.

Klíčová slova

fixation, clinical conditions, K wires

Autoři

PÍŠKA, M.

Rok RIV

2004

Vydáno

1. 1. 1998

Nakladatel

Oxford University

Místo

Oxford University

ISSN

0301-620X

Periodikum

Journal of Bone and Joint Surgery

Ročník

1

Číslo

1

Stát

Spojené království Velké Británie a Severního Irska

Strany od

23

Strany do

23

Strany počet

1

BibTex

@article{BUT41178,
  author="Miroslav {Píška}",
  title="Rigid olecranon fixation: A comparison of two techniques",
  journal="Journal of Bone and Joint Surgery",
  year="1998",
  volume="1",
  number="1",
  pages="23--23",
  issn="0301-620X"
}