DREXLER, P. FIALA, P.
Originální název
Methods for High Power EM Pulse Measurement
Typ
článek v časopise - ostatní, Jost
Jazyk
angličtina
Originální abstrakt
There are some suitable methods for the measurement of ultra-short solitary electromagnetic pulses that can be generated by high power pulsed generators. The measurement methods properties have to correspond to the fact whether we want to measure pulses of voltage, current or free-space electromagnetic wave. The need for specific measurement methods occurred by the development of high power microwave pulse generator [1]. Applicable methods are presented in this paper. The method utilizing Faraday's induction law allows the measurement of generated current. For the same purpose the magneto-optic method can be utilized, with its advantages. For measurement of output microwave pulse of the generator the calorimetric method was designed and realized.
Klíčová slova
EMC, electromnagnetic puls, pus generator
Autoři
DREXLER, P.; FIALA, P.
Rok RIV
2006
Vydáno
1. 1. 2006
ISSN
1210-2512
Periodikum
Radioengineering
Ročník
15
Číslo
4
Stát
Česká republika
Strany od
43
Strany do
49
Strany počet
7