Detail publikace

Experiments of Accuracy Air Ion Field Measurement

BARTUŠEK, K. FIALA, P. JIRKŮ, T. KROUTILOVÁ, E.

Originální název

Experiments of Accuracy Air Ion Field Measurement

Typ

článek v časopise - ostatní, Jost

Jazyk

angličtina

Originální abstrakt

An analysis of the electric state of air shows the presence of various ion sorts. The therapeutic effect of negative high-mobility ions of proper concentration is known. This positive effect was observed in caves that are used for speleotherapy. This article presents the capability of methods for measuring ion concentration and for ion spectral analysis. Here are new gerdien tube design steps based on numerical analysis and its experimental verification. Article describe of any experiments with different air ion generator.

Klíčová slova

air ion field, gerdien condenser, picoampermeter

Autoři

BARTUŠEK, K.; FIALA, P.; JIRKŮ, T.; KROUTILOVÁ, E.

Rok RIV

2007

Vydáno

27. 8. 2007

Nakladatel

The Electromagnetic Academy

ISSN

1559-9450

Periodikum

Progress In Electromagnetics

Ročník

1

Číslo

1

Stát

Spojené státy americké

Strany od

396

Strany do

399

Strany počet

4

BibTex

@article{BUT44046,
  author="Karel {Bartušek} and Pavel {Fiala} and Tomáš {Jirků} and Eva {Kroutilová}",
  title="Experiments of Accuracy Air Ion Field Measurement",
  journal="Progress In Electromagnetics",
  year="2007",
  volume="1",
  number="1",
  pages="396--399",
  issn="1559-9450"
}