Detail publikace

Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit

SKALKA, M. ONDRŮŠEK, Č. JANDA, M.

Originální název

Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit

Typ

článek v časopise - ostatní, Jost

Jazyk

angličtina

Originální abstrakt

This article contains a solution of electromagnetic field distribution with oversaturated areas localization and description. The rotor position is important for the maximal magnetic circuit saturated identification and oversaturated areas size influence of magnetic circuit due to the variable magnetic resistance of path. Influence of rotor position on saturated magnetic circuit is analyzed with step on twenty angular rotations per rotor slot pitch. This analysis is done for 3-phase 1.1kW induction machine by finite element method. Also, the time behavior of magnetic flux density is analyzed in air gap for different load conditions of machine and general postprocessor results juxtaposition in conclusion.

Klíčová slova

Magnetic Circuit; Magnetic Field; ANSYS; Finite Element Method; Induction Machine

Autoři

SKALKA, M.; ONDRŮŠEK, Č.; JANDA, M.

Rok RIV

2009

Vydáno

23. 7. 2009

Místo

Polsko

ISSN

0239-3646

Periodikum

Zeszyty Problemowe - Maszyny Elektryczne

Ročník

2009

Číslo

84

Stát

Polská republika

Strany od

91

Strany do

97

Strany počet

223

BibTex

@article{BUT48815,
  author="Miroslav {Skalka} and Čestmír {Ondrůšek} and Marcel {Janda}",
  title="Influence of Rotor Position on Oversaturated Areas Size of Induction Machine Magnetic Circuit",
  journal="Zeszyty Problemowe - Maszyny Elektryczne",
  year="2009",
  volume="2009",
  number="84",
  pages="91--97",
  issn="0239-3646"
}