Dead-Time Compensation in Vector Controlled AC System
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
It is necessary to insert a switching delay time in pulse width modulation (PWM) voltage inverters to prevent a short circuit in the DC link. This causes known dead-time effect which evokes distortion of output voltage inverter and ripple of phase current. This paper aims at analyzing and compensating the dead-time effects in the vector-controlled AC system. The results of the experiment show the validity of the analysis and verify the effectiveness of the proposed compensation method. The method can be implemented with software without any extra hardware.
Klíčová slova
dead-time compensation, induction motor, AC drives
Autoři
Rok RIV
2013
Vydáno
25. 4. 2013
Nakladatel
LITERA BRNO, Tábor 43a, 612 00, Brno
Místo
Brno
ISBN
978-80-214-4695-3
Kniha
Proceeding of the 19th Conference STUDENT EEICT 2013
Edice
první
Číslo edice
3
Strany od
67
Strany do
71
Strany počet
5
BibTex
@inproceedings{BUT99501, author="Luděk {Buchta}", title="Dead-Time Compensation in Vector Controlled AC System", booktitle="Proceeding of the 19th Conference STUDENT EEICT 2013", year="2013", series="první", number="3", pages="67--71", publisher="LITERA BRNO, Tábor 43a, 612 00, Brno", address="Brno ", isbn="978-80-214-4695-3" }