Přístupnostní navigace
E-application
Search Search Close
Publication detail
HEGER, Z. ZÍTKA, J. CERNEI, N. KŘÍŽKOVÁ, S. SZTALMACHOVÁ, M. KOPEL, P. MASAŘÍK, M. HODEK, P. ZÍTKA, O. ADAM, V. KIZEK, R.
Original Title
3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein
Type
journal article in Web of Science
Language
English
Original Abstract
Currently, metallothioneins (MTs) are extensively investigated as the molecular biomarkers and the significant positive association of the MT amount was observed in tumorous versus healthy tissue of various types of malignant tumors, including head and neck cancer. Thus, we proposed a biosensor with fluorescence detection, comprising paramagnetic nanoparticles (nanomaghemite core with gold nanoparticles containing shell) for the magnetic separation of MT, based on affinity of its sulfhydryl groups toward gold. Biosensor was crafted from PDMS combined with technology of 3D printing and contained reservoir with volume of 50 L linked to input (sample/detection components and washing/immunobuffer) and output (waste). For the immunolabeling of immobilizedMT anti-MT antibodies conjugated toCdTe quantum dots through synthetic heptapeptide were employed. After optimization of fundamental conditions of the immunolabeling (120 min, 20°C, and 1250 rpm) we performed it on a surface of paramagnetic nanoparticles in the biosensor reservoir, with evaluation of fluorescence of quantum dots (exc 400 nm, and em 555 nm). The developed biosensor was applied for quantification of MT in cell lines derived from spinocellular carcinoma (cell line 122P-N) and fibroblasts (122P-F) and levels of the biomarker were found to be about 90 nM in tumor cells and 37 nM in fibroblasts. The proposed system is able to work with low volumes ( 100 L), with low acquisition costs and high portability.
Keywords
Biosensor, Bioseparation, Head and neck cancer, Metallothionein, Nanotechnology
Authors
HEGER, Z.; ZÍTKA, J.; CERNEI, N.; KŘÍŽKOVÁ, S.; SZTALMACHOVÁ, M.; KOPEL, P.; MASAŘÍK, M.; HODEK, P.; ZÍTKA, O.; ADAM, V.; KIZEK, R.
RIV year
2015
Released
1. 6. 2015
ISBN
0173-0835
Periodical
Electrophoresis
Year of study
36
Number
11-12
State
Federal Republic of Germany
Pages from
1256
Pages to
1264
Pages count
9
BibTex
@article{BUT115883, author="Zbyněk {Heger} and Jan {Zítka} and Natalia Vladimirovna {Cernei} and Soňa {Křížková} and Markéta {Svobodová} and Pavel {Kopel} and Michal {Masařík} and Petr {Hodek} and Ondřej {Zítka} and Vojtěch {Adam} and René {Kizek}", title="3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein", journal="Electrophoresis", year="2015", volume="36", number="11-12", pages="1256--1264", doi="10.1002/elps.201400559", issn="0173-0835" }