Detail publikace

3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein

HEGER, Z. ZÍTKA, J. CERNEI, N. KŘÍŽKOVÁ, S. SZTALMACHOVÁ, M. KOPEL, P. MASAŘÍK, M. HODEK, P. ZÍTKA, O. ADAM, V. KIZEK, R.

Originální název

3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

Currently, metallothioneins (MTs) are extensively investigated as the molecular biomarkers and the significant positive association of the MT amount was observed in tumorous versus healthy tissue of various types of malignant tumors, including head and neck cancer. Thus, we proposed a biosensor with fluorescence detection, comprising paramagnetic nanoparticles (nanomaghemite core with gold nanoparticles containing shell) for the magnetic separation of MT, based on affinity of its sulfhydryl groups toward gold. Biosensor was crafted from PDMS combined with technology of 3D printing and contained reservoir with volume of 50 L linked to input (sample/detection components and washing/immunobuffer) and output (waste). For the immunolabeling of immobilizedMT anti-MT antibodies conjugated toCdTe quantum dots through synthetic heptapeptide were employed. After optimization of fundamental conditions of the immunolabeling (120 min, 20°C, and 1250 rpm) we performed it on a surface of paramagnetic nanoparticles in the biosensor reservoir, with evaluation of fluorescence of quantum dots (exc 400 nm, and em 555 nm). The developed biosensor was applied for quantification of MT in cell lines derived from spinocellular carcinoma (cell line 122P-N) and fibroblasts (122P-F) and levels of the biomarker were found to be about 90 nM in tumor cells and 37 nM in fibroblasts. The proposed system is able to work with low volumes ( 100 L), with low acquisition costs and high portability.

Klíčová slova

Biosensor, Bioseparation, Head and neck cancer, Metallothionein, Nanotechnology

Autoři

HEGER, Z.; ZÍTKA, J.; CERNEI, N.; KŘÍŽKOVÁ, S.; SZTALMACHOVÁ, M.; KOPEL, P.; MASAŘÍK, M.; HODEK, P.; ZÍTKA, O.; ADAM, V.; KIZEK, R.

Rok RIV

2015

Vydáno

1. 6. 2015

ISSN

0173-0835

Periodikum

Electrophoresis

Ročník

36

Číslo

11-12

Stát

Spolková republika Německo

Strany od

1256

Strany do

1264

Strany počet

9

BibTex

@article{BUT115883,
  author="Zbyněk {Heger} and Jan {Zítka} and Natalia Vladimirovna {Cernei} and Soňa {Křížková} and Markéta {Svobodová} and Pavel {Kopel} and Michal {Masařík} and Petr {Hodek} and Ondřej {Zítka} and Vojtěch {Adam} and René {Kizek}",
  title="3D-printed biosensor with poly(dimethylsiloxane) reservoir for magnetic separation and quantum dots-based immunolabeling of metallothionein",
  journal="Electrophoresis",
  year="2015",
  volume="36",
  number="11-12",
  pages="1256--1264",
  doi="10.1002/elps.201400559",
  issn="0173-0835"
}