Publication detail

The Mini Labyrinth Benchmark for Radiation Protection and Shielding Analysis

VRBAN, B. ČERBA, Š. LÜLEY, J. NEČAS, V. FILOVÁ, V. KATOVSKÝ, K. ŠŤASTNÝ, O. GLOGINJIC, M. ERICH, M. MRAVIK, Ž. PETROVIC, S.

Original Title

The Mini Labyrinth Benchmark for Radiation Protection and Shielding Analysis

Type

journal article in Web of Science

Language

English

Original Abstract

The Mini Labyrinth experiment is a neutron and gamma shielding experiment currently being developed at STU. The STU Mini Labyrinth consists of NEUTRONSTOP shielding blocks, water tank, PuBe neutron source, and graphite prism. This paper describes the second construction version of the Mini Labyrinth experiment and presents the newest results of the neutron and gamma fields simulation and measurement. The PuBe neutron source with the emission rate of 1.06E7 n/s was used in the experiment. The measurement of gamma ambient dose equivalent H*(10) and neutron count rates is performed by the Thermo Scientific RadEye portable survey meter and the SNM-11 BF3 corona detector. The simulation part was carried out using state-of-the-art MCNP6 and SCALE6 MONACO stochastic calculation tools, considering the detailed geometry of the Mini Labyrinth and a combined neutron and gamma source of particles. The comparisons were performed between codes and the experiment. The propagation of the cross-section uncertainties was investigated through the shielding analysis. Almost perfect agreements between simulation codes were achieved. The comparison with measurement suggests the further needs of room effect assesment.

Keywords

radiation shielding; experiment; calculation; cross-section uncertainties; labyrinth

Authors

VRBAN, B.; ČERBA, Š.; LÜLEY, J.; NEČAS, V.; FILOVÁ, V.; KATOVSKÝ, K.; ŠŤASTNÝ, O.; GLOGINJIC, M.; ERICH, M.; MRAVIK, Ž.; PETROVIC, S.

Released

4. 4. 2022

Publisher

IEEE

Location

IEEE, USA

ISBN

0018-9499

Periodical

IEEE TRANSACTIONS ON NUCLEAR SCIENCE

Year of study

69

Number

4

State

United States of America

Pages from

745

Pages to

752

Pages count

8

URL

BibTex

@article{BUT175116,
  author="Branislav {Vrban} and Štefan {Čerba} and Jakub {Lüley} and Vladimír {Nečas} and Vendula {Filová} and Karel {Katovský} and Ondřej {Šťastný} and Marko {Gloginjic} and Marko {Erich} and Željko {Mravik} and Srdjan {Petrovic}",
  title="The Mini Labyrinth Benchmark for Radiation Protection and Shielding Analysis",
  journal="IEEE TRANSACTIONS ON NUCLEAR SCIENCE",
  year="2022",
  volume="69",
  number="4",
  pages="745--752",
  doi="10.1109/TNS.2022.3144838",
  issn="0018-9499",
  url="https://ieeexplore.ieee.org/document/9686683"
}