The Mini Labyrinth Benchmark for Radiation Protection and Shielding Analysis
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
The Mini Labyrinth experiment is a neutron and gamma shielding experiment currently being developed at STU. The STU Mini Labyrinth consists of NEUTRONSTOP shielding blocks, water tank, PuBe neutron source, and graphite prism. This paper describes the second construction version of the Mini Labyrinth experiment and presents the newest results of the neutron and gamma fields simulation and measurement. The PuBe neutron source with the emission rate of 1.06E7 n/s was used in the experiment. The measurement of gamma ambient dose equivalent H*(10) and neutron count rates is performed by the Thermo Scientific RadEye portable survey meter and the SNM-11 BF3 corona detector. The simulation part was carried out using state-of-the-art MCNP6 and SCALE6 MONACO stochastic calculation tools, considering the detailed geometry of the Mini Labyrinth and a combined neutron and gamma source of particles. The comparisons were performed between codes and the experiment. The propagation of the cross-section uncertainties was investigated through the shielding analysis. Almost perfect agreements between simulation codes were achieved. The comparison with measurement suggests the further needs of room effect assesment.
Klíčová slova
radiation shielding; experiment; calculation; cross-section uncertainties; labyrinth
Autoři
VRBAN, B.; ČERBA, Š.; LÜLEY, J.; NEČAS, V.; FILOVÁ, V.; KATOVSKÝ, K.; ŠŤASTNÝ, O.; GLOGINJIC, M.; ERICH, M.; MRAVIK, Ž.; PETROVIC, S.
Vydáno
4. 4. 2022
Nakladatel
IEEE
Místo
IEEE, USA
ISSN
0018-9499
Periodikum
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
Ročník
69
Číslo
4
Stát
Spojené státy americké
Strany od
745
Strany do
752
Strany počet
8
URL
https://ieeexplore.ieee.org/document/9686683
BibTex
@article{BUT175116, author="Branislav {Vrban} and Štefan {Čerba} and Jakub {Lüley} and Vladimír {Nečas} and Vendula {Filová} and Karel {Katovský} and Ondřej {Šťastný} and Marko {Gloginjic} and Marko {Erich} and Željko {Mravik} and Srdjan {Petrovic}", title="The Mini Labyrinth Benchmark for Radiation Protection and Shielding Analysis", journal="IEEE TRANSACTIONS ON NUCLEAR SCIENCE", year="2022", volume="69", number="4", pages="745--752", doi="10.1109/TNS.2022.3144838", issn="0018-9499", url="https://ieeexplore.ieee.org/document/9686683" }