Originální abstrakt

The effect of plasma electrolytic oxidation (PEO) on the fatigue of AZ61 magnesium alloy has been investigated under high cycle conditions in air and 3.5% NaCl solution. PEOemployed an alkaline pyrophosphate-silicate-fluoride electrolyte, with an offset square waveform, a frequency of 50 Hz, and current density of 130 mA cm-2.The PEO treatment led to reductions in the fatigue limit by 38% in air and by 56% in 3.5% NaCl solution. The reduction of the fatigue limit is attributed to cracking of the coating, roughness of the alloy/coating interface, corrosion and influences of Al-Mn particles.

Klíčová slova

magnesium, SEM, corrosion fatigue, oxide coatings

Autoři

NĚMCOVÁ, A.; SKELDON, P.; THOMPSON, G.; MORSE, S.; ČÍŽEK, J.; PACAL, B.

Rok RIV

2014

Vydáno

1. 5. 2014

Nakladatel

Elsevier

ISSN

0010-938X

Periodikum

CORROSION SCIENCE

Ročník

2014

Číslo

82

Stát

Spojené království Velké Británie a Severního Irska

Strany od

58

Strany do

66

Strany počet

9

URL

Plný text v Digitální knihovně

BibTex

@article{BUT106476,
  author="Aneta {Němcová} and Peter {Skeldon} and George {Thompson} and Stuart {Morse} and Jan {Čížek} and Bohumil {Pacal}",
  title="Influence of plasma electrolytic oxidation on fatigue performance of AZ61 magnesium alloy",
  journal="CORROSION SCIENCE",
  year="2014",
  volume="2014",
  number="82",
  pages="58--66",
  doi="10.1016/j.corsci.2013.12.019",
  issn="0010-938X",
  url="http://www.sciencedirect.com/science/article/pii/S0010938X13005945"
}